Fluke 1730 Three-Phase Electrical Energy Logger

Fluke 1730 enables users to capture the data they need to make energy savings in their facilities.

By discovering where, when and how much energy is being used allows energy usage to be compared with activity in the facility.

Overview

Discover where you’re wasting energy and reduce your energy bill.

Fluke 1730 enables users to capture the data they need to make energy savings in their facilities.

By discovering where, when and how much energy is being used allows energy usage to be compared with activity in the facility.

1730 consists of measurement hardware and application software so that data can be collected and reports created with the minimum of effort.
The 1730 instrument is incredibly easy to use; it even makes automatic checks to ensure the user has connected the leads and current sensors up correctly.

There are several ways to power the new Fluke 1730 energy logger the first one is simply just to power.

the unit on using the internal battery that comes with the unit you can also use an external battery here to extend the life and allow you to do longer studies or longer troubleshooting.

While out in the field now with that said you can take this plug it on to the back and use that individually. like this, you can also charge this battery via your ports at the top whether you using AC power and a wall outlet.

This you can just plug in here plug into the wall and then you can simply plug it on to the base of the unit this.

Then allows you to go ahead and charge the unit and use that power while you are doing your study another way that you can go ahead and charge this unit is to simply disconnect your AC power.

You can actually use the power that you are Measuring to go ahead and charge the battery here itself by using a couple of jumper leads.
Here you can plug these into the top of a unit depending upon whether you have Delta or a Wye configuration this.

One will be plugged into maybe the neutral or the l2 depending upon your set your system setup if you were using the battery externally and you wanted to go ahead and take that off.

Because of space constraints, you can either have this side by side the units and have it connected via a connector here about three-foot connector you can go ahead and plug this into the base. That the way actually measuring with Fluke 1730/EUS Three-Phase Electrical Energy Logger.

Features

  • Key measurements: Voltage, current, power, power factor and associated values enable you to optimize and implement your energy saving strategies.
  • Bright, color touch screen: Perform convenient in-the-field analysis and data checks with full graphical display.
  • Power the instrument directly from the measured circuit: Eliminating the need to find a power outlet while allowing the instrument to be secured safely inside electrical panels. Wide voltage range from 90V to 550V AC.
  • Comprehensive logging: More than 20 separate logging sessions can be stored on the instrument. In fact, all measured values are automatically logged and can be reviewed during logging and before downloading for on-the-go analysis.
  • Two USB ports: One for WiFi or direct PC connection and another for fast, simple download to standard USB thumb drives, or other USB devices (WiFi requires external USB WiFi adaptor).
  • Optimized user interface: Capture the right data every time with quick, guided, graphical setup and reduce uncertainty about your connections with the intelligent verification function.
  • Complete “in-the-field” setup through the front panel: No need to return to the workshop for download and setup or to take a computer to the electrical panel.
  • Compact size: Designed to fit in tight spaces and panels.
  • Highest safety rating in the industry: 600 V CAT IV/1000 V CAT III rated for use at the service entrance and downstream.
  • Optimized measurement accessories: Flat voltage cable and thin flexible current probes ensure easy installation even in tight spaces.
  • Battery life: Four-hour operating time (backup time) per charge on lithium-ion battery.
  • Security: We safeguard your best asset from theft with an option to use a hefty, durable Kensington lock.
  • Energy Analyze application software: Download and analyze a snapshot of your energy savings potential with our automated reporting – export data into RTF for editing with you preferred word processing application.

Specifications

Display Color transmissive LCD 320 x 240 pixels (70 mm diagonal) with 2 level backlight
Power supply Battery type 1.5 V Alkaline AA MN 1500 or IEC LR6 x 6
Battery life typically > 10 hours (backlight on full)
> 12 hours (backlight reduced)
Battery eliminator Input 110/230 V 50/60 Hz
Output 15 VDC, 300 mA
Ambient conditions (for indoor use only)
Reference conditions All accuracies stated at 23°C ±1°C (73.4°F ±1.8°F)
Operating temperature 0°C to 50°C (32°F to 122°F)
Temperature coefficient of current ≤ ±0.15% of rdg per °C
Temperature coefficient of voltage ≤ ±0.15% of rdg per °C
Maximum relative humidity 80% for temperatures up to 31°C (87°F) decreasing linearly to 50% relative humidity at 40°C (104°F)
Maximum operating altitude 2000 m
Electrical safety
Maximum safe working voltages Safety IEC 61010-1 600 V CAT IV double or reinforced insulation, pollution degree 2
Protection IP40; EN60529
Current measurement 600 VAC rms or DC between uninsulated conductor and ground
Voltage measurement 600 VAC rms or DC between either input terminal and ground, or 825 V between energized phase voltages (delta power config.)
EMC
Emission IEC/EN 61326-1:1997 A
Immunity IEC/EN 61326-1:1997 Annex C Performance Criterion B
Mechanical
Dimensions (L x W x D) 300 x 98 x 52 mm (12 x 3.75 x 2 in)
Weight including batteries 820 g (1.8 lb)
Jaw opening 60 mm
Jaw capacity 58 mm diameter
Cleaning The unit can be cleaned with an Isopropanol impregnated cloth. Do not use abrasives or other solvents.
Electrical data
Accuracy 23°C ±1°C (73.4°F ±1.8°F). See Ambient conditions specifications for temperature coefficients.
Current measurement (DC, DC rms, AC rms)
Measuring range 0 to 2000 A DC or 1400 AC rms
Autorange facility 40 A / 400 A / 2000 A
Resolution 10 mA in 40 A range
100 mA in 400 A range
A in 2000 A range
Accuracy: DC and DC rms I > 10 A ±1.5% rdg ±5 digits
I < 10 A ±0.2 A
Accuracy: AVG I > 10 A ±3% rdg ±5 digits
I < 10 A ±0.5 A
Accuracy: Pk I > 10 A ±5% rdg ±5 digits
I < 10 A ±0.5 A
Accuracy: AHr I > 10 A ±2% rdg ±5 digits
I < 10 A ±0.5 AHr
Accuracy: CF (Crest Factor) 1.1 ≤ CF < 3 ±3% rdg ±5 digits
3 ≤ CF < 5 ±5% rdg ±5 digits
Resolution 0.01
Accuracy: RPL (Ripple) 2% ≤ RPL < 100%  ±3% rdg ±5 digits
100% ≤ RPL < 600% ±5% rdg ±5 digits
Resolution 0.1%
I DC > 5 A, I AC > 2 A
All measurements DC and 15 Hz to 1 kHz
Maximum overload 10,000 A or rms x frequency < 400,000
Amps rms is a true-rms measurement (AC + DC)
Voltage measurement (DC, DC rms, AC rms)
Measuring range 0 to 825 VDC or AC rms
Autorange facility 4 V / 40 V / 400 V / 750 V
Resolution 1 mV in 4 V range
10 mV in 40 V range
100 mV in 400 V range
1 V in 750 V range
Accuracy: DC and DC rms V > 1 V ±1% rdg ±5 digits
V < 1 V ±0.02 V
Accuracy: AVG V > 1 V ±3% rdg ±5 digits
V < 1 V ±0.03 V
Accuracy: Pk V > 1 V ±5% rdg ±5 digits
V < 1 V ±0.03 V
Accuracy: CF (Crest Factor) 1.1 ≤ CF < 3 ±3% rdg ±5 digits
3 ≤ CF < 5 ±5% rdg ±5 digits
Resolution 0.01
Accuracy: RPL (Ripple) 2% ≤ RPL < 100% ±3% rdg ±5 digits
100% ≤ RPL < 600% ±5% rdg ±5 digits
Resolution 0.1%
VDC > 0.5 V, VAC > 0.2 V
All measurements DC and 15 Hz to 1 kHz
Maximum overload 1,000 V rms
Volts rms is a true-rms measurement (AC + DC)
Harmonics
THD (Total Harmonic Distortion) 1% ≤ THD < 100% ±3% rdg ±5 digits
100% ≤ THD < 600% ±5% rdg ±5 digits
Resolution 0.1%
DF (Distortion Factor) 1% ≤ DF < 100% ±3% rdg ±5 digits
Resolution 0.1%
H02 ≤ Vharm < H13 ±5% ±2 digits
H13 ≤ Vharm ≤ H30 ±10% ±2 digits
All measurements up to 30th harmonic (40th harmonic for 15 Hz to 22 Hz)
Frequency range of fundamental F0 15 Hz to 22 Hz and 45 Hz to 65 Hz
Vacrms > 1V
Watts measurement (single and three-phase) (DC, DC rms, AC rms)
Measuring range 0 to 1650 kW DC or 1200 kW AC
Measuring range 4 kW, 40 kW, 400 kW, 1650 kW
Resolution 1 W in 4 kW
10 W in 40 kW
100 W in 400 kW
1 kW in 1200 kW
Accuracy 2.5% rdg ±5 digits
W1Ø < 2 kW ±0.08 kW
W3Ø < 4 kW ±0.25 kW
VA measurement (single- and three-phase) (DC, DC rms, AC rms)
Measuring range 0 to 1650 kVA DC or 1200 kVA AC
Autorange facility 4 kVA, 40 kVA, 400 kVA, 1650 kVA
Resolution 1 VA in 4 kVA
10 VA in 40 kVA
100 VA in 400 kVA
1 kVA in 1200 kVA
Accuracy VA > 2 kVA 2.5% rdg ±5 digits
VA < 2 kVA ±0.08 kVA
VAR measurement (single- and three-phase)
Measuring range 0 to 1250 kVAR
Autorange facility 4 kVAR, 40 kVAR, 400 kVAR, 1200 kVAR
Resolution 1 VAR in 4 kVAR
10 VAR in 40 kVAR
100 VAR in 400 kVAR
1 kVAR in 1200 kVAR
Accuracy VAR > 4 kVAR ±2.5% rdg ±5 digits
VAR < 4 kVAR ±0.25 kVAR
Power factor range 0.3 < PF < 0.99
Power factor (single- and three-phase)
Measuring range 0.3 capacitive to 1.0 and 1.0 to 0.3 inductive (72.5° capacitive to 0° and 0° to 72.5° inductive)
Resolution 0.001
Accuracy ±3°
Frequency range 15 Hz to 1 kHz
Displacement power factor (single- and three-phase)
Measuring range 0.3 capacitive to 1.0 and 1.0 to 0.3 inductive (72.5° capacitive to 0° and 0° to 72.5° inductive)
Resolution 0.001
Accuracy ±3°
Frequency range 15 Hz to 22 Hz and 45 Hz to 65 Hz
Kilowatt hour (kWHr)
Measuring range 40,000 kWHr
Autorange facility 4 kWHr, 40 kWHr, 400 kWHr, 4,000 kWHr, 40,000 kWHr
Resolution 1 WHr in 4 kWHr Range
10 WHr in 40 kWHr Range
100 WHr in 400 kWHr Range
1 kWHr in 4,000 kWHr Range
10 kWHr in 40,000 kWHr Range
Accuracy kWHr > 2 kWHr ±3% ±5 digits
kWHr < 2 kWHr ±0.08 kWHr
All Watts /VA /VAR /PF measurements Frequency range DC and 15 Hz to 1 kHz
Current range 10 A to 1400 A rms
Voltage range 1 V to 825 V rms
Maximum input 825 V rms / 1400 A rms
Maximum overload 1000 V rms / 10,000 A All measurements DC and 15 Hz to 1 kHz. Maximum overload 10,000 A or rms x frequency < 400,000
Frequency measurement (from current or voltage sources)
Measuring range 15 Hz to 1 kHz
Resolution 0.1 Hz
Accuracy 15 to 22 Hz ±0.5% rdg
40 Hz to 70 Hz ±0.5% rdg
15 Hz to 1000 Hz ±1% rdg
Current range 10 A to 1400 A rms
Voltage range 1 V to 825 V rms
Scope function
Current measurement Range 10 A / 20 A / 40 A / 100 A / 200 A / 400 A / 1000 A / 2000 A
Resolution 1 A in 40 A
10 A in 400 A
50 A in 2000 A
Accuracy ±3% rdg ±1 pixel
Maximum overload 10,000 A
Voltage measurement Range 4 V / 10 V / 20 V / 40 V / 100 V / 200 V / 400 V / 1000 V
Resolution 100 mV in 4 V
1 V in 40 V
10 V in 400 V
31.25 V in 1000 V
Accuracy ±2% rdg ±1 pixel
Maximum overload 1000 V rms
Frequency range DC and 15 Hz to 600 Hz
Time base 2.5 ms, 5 ms, 10 ms, 25 ms, 50 ms/div
Refresh rate 0.5 seconds
Maximum sampling rate 15.625 kHz
Inrush current function
Ranges 40 A, 400 A, and 2000 A
Resolution 10 mA in 40 A range
100 mA in 400 A range
1 A in 2000 A range
Accuracy I > 10 A ±5% rdg ±1 pixel
I < 10 A ±0.5 A
All measurements DC and 15 Hz to 1 kHz
Maximum overload Maximum overload 10,000 A or rms x frequency < 400,000
Amps rms is a true-rms measurement (AC + DC)
Capture time 1 s, 3 s, 10 s, 30 s, 100 s, and 300 s
Maximum sampling rate 15.625 kHz
Interface
USB Interface to a PC Power Log software for download, analysis and reporting
345 Upgrade Utility for installing a new firmware version
Logging Memory
Logging areas Three areas that can be used individually or combined into one large area
Averaging periods 1 s, 2 s, 5 s, 10 s, 30 s, 1 min, 5 min, 10 min, 15 min, and custom
Logging Times
Volts and current mode Average time Logging time (1 area)
1 s 1 h 49 m
2 s 3 h 38 m
5 s 9 h 6 m
10 s 18 h 12 m
30 s 2 d 6 h 36 m
1 min 4 d 13 h 12 m
5 min 22 d 18 h 0 m
10 min 45 d 12 h 0 m
15 min 68 d 6 h 0 m
Logging time (3 areas)
1 s 5 h 12 m
2 s 10 h 24 m
5 s 1 d 2 h 00 m
10 s 2 d 4 h 00 m
30 s 6 d 12 h 1 m
1 min 13 d 0 h 12 m
5 min 65 d 0 h 15 m
10 min 130 d 0 h 30 m
15 min 195 d 0 h 45 m
V and A harmonics mode Average time Logging time (1 area)
1 s 0 h 34 m
2 s 1 h 8 m
5 s 2 h 52 m
10 s 5 h 44 m
30 s 17 h 13 m
1 m 1 d 10 h 26 m
5 m 7 d 4 h 10 m
10 m 14 d 8 h 20 m
15 m 21 d 12 h 30 m
Logging time (3 areas)
1 s 1 h 38 m
2 s 3 h 16 m
5 s 8 h 11 m
10 s 16 h 23 m
30 s 2 d 1 h 11 m
1 m 4 d 2 h 23 m
5 m 20 d 11 h 25 m
10 m 81 d 0 h 50 m
15 m 121 d 13 h 15 m
Single- and three-phase power mode Average time Logging time (1 area)
1 s 1 h 40 m
2 s 3 h 21 m
5 s 8 h 22 m
10 s 16 h 45 m
30 s 2 d 2 h 17 m
1 m 4 d 4 h 35 m
5 m 20 d 22 h 55 m
10 m 41 d 21 h 50 m
15 m 62 d 20 h 45 m
Logging time (3 areas)
1 s 4 h 47 m
2 s 9 h 34 m
5 s 23 h 57 m
10 s 1 d 23 h 54 m
30 s 5 d 23 h 25 m
1 m 11 d 23 h 25 m
5 m 59 d 21 h 5 m
10 m 119 d 18 h 10 m
15 m 179 d 15 h 15 m

Includes

  • 1 x Fluke 1730 Three Phase Electrical Energy Logger
  • 4 x Voltage leads
  • 1 x Software
  • 1 x Soft-sided Carry case
  • 1 x User Documentation

Resources

Fluke 1730 Three-Phase Electrical Energy Logger – Catalog    Download

Accessories

Cables & Hardware
Model Name Description
Fluke 1730 Cable 1730 Energy Logger auxiliary input cable
Fluke 1730 Hanger Fluke 1730 Hanger Strap Kit
Cases & Holsters
Model Name Description
C1730 Fluke C1730 Soft Case
Current Clamps
Model Name Description
Fluke i1730-flex1500 Fluke i1730-flex1500 iFlex® Current Clamp
Fluke i1730-flex1500/3pk Fluke i1730-flex1500/3pk iFlex® Current Clamps
Fluke i1730-flex3000 Fluke i1730-flex3000 iFlex® Current Clamp
Fluke i1730-flex3000/3pk Fluke i1730-flex3000/3pk iFlex® Current Clamps
Fluke i1730-flex6000 Fluke i1730-flex6000 iFlex® Current Clamp
Fluke i1730-flex6000/3pk Fluke i1730-flex6000/3pk iFlex® Current Clamps
Fluke i40s-EL Fluke i40s-EL 40A Clamp-on Current Transformer
Fluke i40s-EL/3pk Fluke i40s-EL/3pk Clamp-on Current Transformers
Test Leads
Model Name Description
Fluke 1730-TL0.1M Fluke 1730-TL0.1M Test Lead Set
Fluke 1730-TL2M Fluke 1730-TL2M Test Lead Set
Fluke 3PHVL-1730 Fluke 3PHVL-1730 Cable Assembly, Voltage Test Lead
Test Leads, Probes & Clips
Model Name Description
Fluke WC100 Fluke WC100 Color Localization Set

 