Fluke 43B Single Phase Power Quality Analyzer

Fluke 43BPower Quality Analyzer has done the tricks for you. It works Very smart way.

Fluke 43B find your problem so faster. Surely you can depend on this product value.

Overview

Are you Needed to maintain power systems?

Fluke 43BPower Quality Analyzer has done the tricks for you. It works Very smart way.

Fluke 43B find your problem so faster. Surely you can depend on this product value.

Safety Information, Read First
Read the safety information before using the Fluke 43B.

If Safety-Precautions are Impaired
Using the Fluke 43B in a manner not specified may impair the protection
Provided by the equipment. Before using, inspect the test leads for
Mechanical damage and replace damaged test leads!
If it is likely that safety has been impaired, turn the Fluke 43B off and disconnect
It from the line power.

The matter should then be referred to qualified personnel.
Safety is likely to be impaired if, for example, the Fluke 43B fails to perform the
Intended measurements or shows visible damage.

Do not use a probe that is cracked, damaged, or has a defective cable.

Such probes should be made inoperative by taping the clamp shut to prevent
Operation.

Fluke’s single phase analyzers perform the measurements you need to maintain power systems and troubleshoot power problems and diagnose equipment failures.

Monitoring functions help track intermittent problems and power system performance.

Fluke 43B Power Quality Analyzer performs the measurements you, troubleshoot power problems and diagnose equipment failures.

This versatile tool combines the most useful capabilities of a power quality analyzer, multimeter and scope—all in a rugged handheld package.

More accurately you can also calculate 3 phase power on balanced loads, from a single-phase measurement.

Use Fluke 43B to measure resistance, diode voltage drop, continuity, and capacitance or to trend voltage, current, frequency, power harmonics and captures voltage sags, transients and inrush current.

With Fluke 43BPower Quality Analyzer surely you can maintain power systems, troubleshoot power problems, and diagnose equipment failures.

In Bangladesh Fluke Bangladesh is a fluke agent that you can trust on. Fluke Bangladesh is a dependable supplier in Bangladesh. So, your scope is awesome to collect the best fluke product you always looking for.

Features

Combines the most useful capabilities of a power quality analyzer, multimeter and scope

    • NiMH Battery provides an extended operating time of 6.5 hours
    • Calculates 3-phase power on balanced loads, from a single-phase measurement
    • Trends voltage, current, frequency, power harmonics and captures voltage sags, transients and inrush current
    • Monitoring functions help track intermittent problems and power system performance
    • Records two selectable parameters for up to 16 days
    • 20 measurement memories to save/recall screens and data with cursor readings
    • FlukeView® software can log harmonics and all other readings over time and provides a complete harmonics profile up to the 51st harmonic
    • Measures resistance, diode voltage drop, continuity, and capacitance
    • Users/applications manual and power quality video to help answer tough questions
    • Complete package with voltage probes and 400 A current clamp, FlukeView Software and optically isolated interface cable
    • 3 year warranty on the Fluke 43B, 1 year on accessories


    Harmonics

    • Voltage, current, and power harmonics
    • Up to 51st harmonic
    • Total harmonic distortion (THD)
    • A phase angle of individual harmonics



    Power

    • Watts, power factor, displacement power factor (cos Θ), VA and VAR
    • Voltage and current waveforms



    Three phase

    • On-screen graphics show you how to set up 3-phase power measurements



    Sags and swells

    • Measurements are always automatically recorded to instantly show changes over time
    • Use cursors to read time and date of sags and swells



    Transients

    • Catch voltage transients and waveform distortion down to 40 nS
    • Catch and save up to 40 transients
    • Correlate the cause of transient with time and date stamps



    Volts/Ampères/Hertz

    • Voltage and current waveforms
    • True RMS voltage and current
    • Frequency

Specifications

Specifications
Input characteristics Input impedance 1 MΩ, 20 pF
Voltage rating 600 V rms, CAT III
V/A/Hz display True-rms voltage
(AC + DC)
Ranges 5.000 V, 50.00 V, 500.0 V, 1250 V1
Accuracy ±(1% + 10 counts)
True-rms current
(AC + DC)
Ranges 50.00 A, 500.0 A, 5.000 kA, 50.00 kA, 1250 kA
Accuracy ±(1% + 10 counts)
Frequency Ranges 10.0 to 15.0 kHz
Accuracy ± ([% of reading] + [counts]): 0.5% + 2
CF crest factor Ranges 1.0 – 10.0
Accuracy ±(5% + 1 count)
Power display Watts, VA, VAR 1-phase and 3-phase,3 conductor balanced loads
Ranges 250 W – 1.56 GW
Accuracy ±(4% + 4 counts) Fundamental Power
Accuracy ± (2% + 6 counts) Total Power
PF power factor Range 0 – 1.0
Accuracy ±0.04
DPF displacement power factor, Cos .F Range 0.25 – 0.9
Accuracy ±0.04
Range 0.90 – 1.0
Accuracy ±0.03
H2 frequency fundamental Ranges 40.0 to 70.0 Hz
Accuracy ± ([% of reading] + [counts]): 0.5% + 2
Harmonics display Voltage, current, frequency Ranges Fundamental to 51st harmonic
Accuracy VA ±(3% + 2 counts) W ±(5% + 2 counts)
Fundamental 2 to 31st harmonic VA ±(5% +3 counts) W ±(10% +10 counts)
32 to 51st harmonic VA ±(15% +5 counts) W ±(30% +5 counts)
Frequency fundamental Ranges 40 Hz to 70 Hz
Accuracy ±0.25 Hz
Phase Range V, A (Between fundamental and harmonics)
Accuracy ±3° to ±15°
Range W (Between voltage fundamental and current harmonics)
Accuracy ±5° to ±15°
K-factor
(Current and Power)
Range 1.0 to 30.0
Accuracy ±10%
THD total harmonic distortion Range 0.00 – 99.99
Accuracy ±(3% + 8 counts)
Sags and swells Recording times 4 min to 16 days (selectable)
Vrms actual, vrms max, min (AC + DC) Ranges 5.000 V, 50.00 V, 500.0 V, 1250 V1
Accuracy Readings ±(2% +10 counts); Cursor readings ± (2% + 12 counts)
Arms actual, arms max, min (AC + DC) Ranges 50.00 A, 500.0 A, 5.000 kA, 50.00 kA
Accuracy ±(2% +10 counts)
Transient capture Minimum pulse width 40 ns
Useful bandwidth input 1 DC to 1 MHz
Number of transients 40
Voltage threshold settings 20%, 50%, 100%, 200% above or below reference
Reference signal After START, the Vrms and frequency of the signal are measured. From these data a pure sinewave is calculated as reference for threshold setting.
Vpeak min, vpeak max at cursor 10 V, 25 V, 50 V, 125 V, 250 V, 500 V, 1250 V Accuracy: ±5% of full scale
R, C, diode, continuity Resistance ranges 500.0 Ω, 5.000 kΩ, 50.00 kΩ, 500.0 kΩ, 5.000 MΩ, 30.00 MΩ
Resistance accuracy ±(0.6% + 5 counts)
Capacitance ranges 50.00 nF, 500.0 nF, 5.000 µF, 50.00 µF, 500.0 µF
Capacitance accuracy ±(2% + 10 counts)
Diode Ranges 0 to 3.000 V
Diode voltage
Accuracy ±(2% + 5 counts)
Continuity Beeper on at < 30 Ω ± 5 Ω
Max current 0.5 mA
Temperature °C or °F
Inrush current Inrush times 1 s, 5 s, 10 s, 50 s, 100 s, 5 min
Current ranges 1 A, 5 A, 10 A, 50 A, 100 A, 500 A, 1000 A
Cursor readings A peak max at cursor 1 and cursor 2
Accuracy ±5% of full scale
Time between cursors 4 to 235 pixels (1 pixel = inrush time/250) Accuracy: ±(0.2% + 2 pixels)
Temperature
(with accessory)
Range -100 °C – 400 °C
Accuracy ±(0.5% + 5 counts)
Scope display Measurements DC, AC, AC + DC, peak, peak-peak, frequency, duty cycle, phase, pulse width, crest factor
Time ranges 20 ns/div to 60 s/div
Max sampling rate 25 MS/s
Bandwidth Voltage channel [1] 20 MHz at inputs, 1 MHz with TL24 leads
Current channel [2] DC to 15 kHz at inputs, 10 kHz with i400s current clamp
Coupling AC, DC (10 Hz – 3 dB)
Vertical sensitivity 5 mV/div to 500V/div
Vertical resolution 8 bit (256 levels)
Record length 512 samples per channel
Base ranges 60 S/div to 20 nS/div ± (0.4% + 1 pixel)
Timebase modes Normal, roll, single
Pre-trigger Up to 10 divisions
Trigger Source Input 1 or input 2 or automatic selection
Trigger Mode Automatic Connect-and-View™, free Run, and single Shot
Connect-and-view™ Advanced automatic triggering that recognizes signal patterns
Automatically adjusts triggering, timebase and amplitude and displays stable pictures
Memories 20 (screens, settings, data)
Recording Recording times 4 min to 16 days (selectable)
Parameters Choose one or two parameters from one of the groups below
Volts/Ampères/Hertz
Power Watts, VA, VAR, PF, DPF, frequency
Harmonics, THD, volts (Fund. and harmonic), ampères (F&H) watts(F&H)
Frequency (H), %(H) of total, Phase(H), KF
Temperature
Resistance Resistance, diode, continuity, capacitance
Scope DC voltage, DC current, AC voltage, AC current, frequency,
Pulse width + or -, phase, duty cycle + or -, peak max, peak min, peak min-max, crest factor
Environmental specifications Operating temperature 0°C to +50°C
Safety specifications Electrical safety EN 61010-1 CAT III, 600V. CSA listed
Mechanical and general specifications Size 232 x 115 x 50 mm
Weight 1.1 kg
Warranty 3 years
Battery life Rechargeable NiMH pack (charger included), 6.5 hrs extended operating time (continuous)
Shock and vibration Mil 28800E, Type 3, Class III, Style B
Case IP51 (dust, drip, waterproof)

Includes

  • C120 Hard Case
  • TP1 Flat-tipped Slim-Reach™ Test Probes
  • TP4 4 mm Round Slim-Reach™ Test Probes
  • i400s AC Current Clamp
  • OC4USB Optically Isolated USB Interface Adapter
  • BP120MH Rechargeable NiMH Battery Pack (installed)
  • PM 8907 Line Voltage Adapter/Battery Charger
  • SW43W FlukeView™ Power Quality Analyzer Software and Users Manual on CD-ROM
  • Shielded Banana-to-BNC Adapter
  • Users Manual / Application Guide

Resources

Fluke 43B Single Phase Power Quality Analyzer – Catalog    Download

Accessories

Batteries, Chargers & Adapters
Model Name Description
Fluke BP120MH Fluke BP120MH NiMH Battery Pack for Fluke 120 series, Fluke 43 and 43B
Fluke PM8907 Fluke PM8907 Line Voltage Adapter/Battery Charger
Cables & Hardware
Model Name Description
Fluke OC4USB Fluke OC4USB USB Interface Cable
Cases & Holsters
Model Name Description
Fluke C120 Fluke C120 Hard Carrying Case
Fluke C125 Fluke C125 Meter Case
Fluke C43 Fluke C43 Soft Carrying Case
Fluke C550 Fluke C550 Tool Bag
Clips
Model Name Description
Fluke AC220 Fluke AC220 SureGripTM Alligator Clips
Fluke AC285 Fluke AC285 SureGripTM Alligator Clips
Fluke TLK225 Fluke TLK-225 SureGripTM Master Accessory Set
Current Clamps
Model Name Description
Fluke 80i 110s Fluke 80i-110s AC/DC Current Clamp
Fluke i1000s Fluke i1000s AC Current Probe
Fluke i200s Fluke i200s AC Current Clamp
Options
Model Name Description
Fluke BB120 Fluke BB120 Shielded Banana to Female BNC Adapter
Temperature Accessories
Model Name Description
Fluke 80T 150UA Fluke 80T-150UA Universal Temperature Probe
Fluke 80TK Fluke 80TK Thermocouple Module
Test Leads
Model Name Description
Fluke TL220 Fluke TL220 SureGripTM Industrial Test Lead Set
Fluke TL221 Fluke TL221 SureGripTM Test Lead Extension Set
Fluke TL223 Fluke TL223 SureGripTM Electrical Test Lead Set
Fluke TL224 Fluke TL224 SureGripTM Insulated Test Leads
Fluke TL238 Fluke TL238 SureGripTM Test Lead Set for High Energy Environments
Fluke TL27 Fluke TL27 Heavy Duty Test Lead Set
Fluke TL71 Fluke TL71 Premium Test Lead Set
Test Probes
Model Name Description
Fluke TP1 Fluke TP1 Slim Reach Test Probes
Fluke TP4 Fluke TP4 Slim Reach Test Probes
Fluke VPS100 Fluke VPS100 Voltage Probe Set, 100 MHz (red and gray)

 

Reviews

There are no reviews yet.

Be the first to review “Fluke 43B Single Phase Power Quality Analyzer”

Your email address will not be published. Required fields are marked *