Fluke 721 Pressure Calibration Instruments

The Fluke 721 Precision Pressure Calibrator is the perfect instrument for gas authority exchange applications.

It highlights double disconnected weight sensors to enable you to take concurrent static and differential weight estimations with a solitary apparatus.

Overview

Weight alignment and temperature estimation for guardianship exchange applications.

The Fluke 721 and 721Ex Precision Pressure Calibrators with double disconnected weight, sensors are the perfect instrument, for gas guardianship exchange applications enabling you to

take concurrent static and differential weight estimations with a solitary apparatus.

Fluke 721 Precision Pressure Calibrator provides pressure calibration and temperature measurement for custody transfer applications

The Fluke 721 Precision Pressure Calibrator is the ideal tool for gas custody transfer applications. It features dual single-handed pressure sensors to allocate you to let simultaneous static and differential pressure measurements together amid a single tool. And it can be configured by selecting either a 16 psi (1.1 bar) or 36 psi (2.48 bar) low-pressure sensor later toting uphill any of seven tall pressure ranges: 100, 300, 500, 1000, 1500, 3000 or 5000 psi (6.9, 20, 24.5, 69, 103.4, 200, 345 bar).

Features

  • Measures up to 30 V DC, check 24 V loop power supplies
  • Extends pressure measurement range with the connection to external 750P
  • 750 series pressure modules (50 ranges)
  • Provides a large backlit graphic display that can show up to three inputs simultaneously
  • Stores five instrument setups for recall
  • Precision pressure calibrator with dual isolated sensors for gas flow calibration (custody transfer) applications
  • Features two isolated, stainless steel, pressure sensors with 0.025% accuracy
  • Includes Pt100 RTD input for temperature measurement (probe optional)
  • Measures 4 to 20 mA signals
  • Provides internal 24 V loop power supply to power a transmitter under test

Specifications

Fluke 721 Pressure Calibration Instruments

Specifications 1-Year
Fluke-721-1601 Range Resolution Accuracy
Low pressure sensor
-14 psi to +16 psi,
-0.97 bar to 1.1 bar
0.001 psi,
0.0001 bar
0.025% of full scale
High pressure sensor
-12 psi to +100 psi,
-0.83 bar to 6.9 bar
0.01 psi,
0.0001 bar
0.025% of full scale
Fluke-721-1603 Low pressure sensor
-14 psi to +16 psi,
-0.97 bar to 1.1 bar
0.001 psi,
0.0001 bar
0.025% of full scale
High pressure sensor
-12 psi to +300 psi,
-0.83 bar to 20 bar
0.01 psi,
0.001 bar
0.025% of full scale
Fluke-721-1605 Low pressure sensor
-14 psi to +16 psi,
-0.97 bar to 1.1 bar
0.001 psi,
0.0001 bar
0.025% of full scale
High pressure sensor
-12 psi to +500 psi,
-0.83 bar to 34.5 bar
0.01 psi,
0.001 bar
0.025% of full scale
Fluke-721-1610 Low pressure sensor
-14 psi to +16psi,
-0.97 bar to 1.1 bar
0.001 psi,
0.0001 bar
0.025% of full scale
High pressure sensor
0 psi to +1000 psi,
0.00 bar to 69 bar
0.1 psi,
0.001 bar
0.025% of full scale
Fluke-721-1615 Range Resolution Accuracy
Low pressure sensor
-14 psi to +16 psi,
-0.97 bar to 1.1 bar
0.001 psi,
0.0001 bar
0.025% of full scale
High pressure sensor
0 psi to +1500 psi,
0.00 bar to 103.4 bar
0.1 psi,
0.001 bar
0.025% of full scale
Fluke-721-1630 Low pressure sensor
-14 psi to +16 psi,
-0.97 bar to 1.1 bar
0.001 psi,
0.0001 bar
0.025% of full scale
High pressure sensor
0 psi to +3000 psi,
0.00 bar to 200 bar
0.1 psi,
0.01 bar
0.025% of full scale
Fluke-721-1650 Low pressure sensor
-14 psi to +16 psi,
-0.97 bar to 1.1 bar
0.001 psi,
0.0001 bar
0.025% of full scale
High pressure sensor
0 psi to +5000 psi,
0.00 bar to 345 bar
0.1 psi,
0.01 bar
0.035% of full scale
Fluke-721-3601 Range Resolution Accuracy
Low pressure sensor
-14 psi to +36 psi,
-0.97 bar to 2.48 bar
0.001 psi,
0.0001 bar
0.025% of full scale
High pressure sensor
-12 to +100 psi,
-0.83 bar to 6.9 bar
.01 psi,
0.0001 bar
0.025% of full scale
Fluke-721-3603 Low pressure sensor
-14 psi to +36 psi,
-0.97 bar to 2.48 bar
0.001 psi,
0.0001 bar
0.025% of full scale
High pressure sensor
-12 psi to +300 psi,
-0.83 bar to 20 bar
0.01 psi,
0.001 bar
0.025% of full scale
Fluke-721-3605 Low pressure sensor
-14 psi to +36 psi,
-0.97 bar to 2.48 bar
0.001 psi,
0.0001 bar
0.025% of full scale
High pressure sensor
-12 psi to +500 psi,
-0.83 bar to 34.5 bar
0.01 psi,
0.001 bar
0.025% of full scale
Fluke-721-3610 Range Resolution Accuracy
Low pressure sensor
-14 psi to +36 psi,
-0.97 bar to 2.48 bar
0.001 psi,
0.0001 bar
0.025% of full scale
High pressure sensor
0 psi to +1000 psi,
0.00 bar to 69 bar
0.1 psi,
0.001 bar
0.025% of full scale
Fluke-721-3615 Low pressure sensor
-14 psi to +36 psi,
-0.97 bar to 2.48 bar
0.001 psi,
0.0001 bar
0.025% of full scale
High pressure sensor
0 psi to +1500 psi,
0.00 bar to 103.4 bar
0.1 psi,
0.01 bar
0.025% of full scale
Fluke-721-3630 Low pressure sensor
-14 psi to +36 psi,
-0.97 bar to 2.48 bar
0.001 psi,
0.0001 bar
0.025% of full scale
High pressure sensor
0 psi to +3000 psi,
0.00 bar to 200 bar
0.1 psi,
0.01 bar
0.025% of full scale
Fluke-721-3650 Low pressure sensor
-14 psi to +36 psi,
-0.97 bar to 2.48 bar
0.001 psi,
0.0001 bar
0.025% of full scale
High pressure sensor
0 psi to +5000 psi,
0.00 bar to 345 bar
0.1 psi,
0.01 bar
0.035% of full scale
General Specifications
Instrument setup recall Last used on power-up
Environmental Operating temperature -10°C to +50°C
Storage temperature (without batteries) -20°C to +60°C
Altitude 2,000 m
Ingress protection IP-40
Power requirements 6.0 V DC
Battery life >35 hours, typical usage
Batteries required (4) Standard AA cells
Dimensions (H x W x D) 7.9 x 4.3 x 2.3 in (20 x 11 x 5.8 cm)
Weight 03539 kg (1 lb 3 oz)
Connectors/ports pressure Two, 1/8 in NPT, 700P Series Pressure Module; RTD Probe
Electrical and Temperature Measurement 1-Year
Function Range Resolution Accuracy
mA measure 0 to 24 mA 0.001 mA ±0.015% of rdg
±0.002mA
V DC measure 0 to 30 V DC 0.001 V ±0.015% of rdg
±0.002 V
Temperature measure (RTD/ Ohms)1 -40°C to 150°C
(-40°F to 302°F)
0.01°C, 0.01°F ±0.015% of rdg
±0.02 ohms
±0.1°C (±0.2°F)
±0.25°C (±0.45°F) combined uncertainty when using 720 RTD probe accessory
Loop power supply 24 V N/A 24 mA @ 24 V
1. Temperature measurement requires optional Fluke-720RTD Pt-100 RTD probe available as an accessory
Temperature Effect
No effect on accuracy on all functions from 15°C to 35°C
Add ±0.002% F.S./°C for temps outside of 15°C to 35°C
Available Pressure Engineering Units
psi, bar, mbar, kPa, kgcm2, cmH2O @ 4°C, cmH2O @ 20°C, mH2O @ 4°C, mH2O @ 20°C, inH2O @ 4°C, inH2O @ 20°C, inH2O @ 60°F, mmHg @ 0°C, inHg @ 0°C, ftH2O @ 4°C, ftH2O @ 20°C, ftH2O @ 60°F

Includes

Fluke 721 Pressure Calibration Instruments

Includes:

  • Soft case
  • Four (4) AA batteries
  • Manual
  • Traceable calibration certificate
  • Test leads

Resources

Lorem ipsum dolor sit amet, consectetur adipiscing elit. Sed mollis placerat accumsan. Phasellus a purus eu odio blandit imperdiet. Integer eu porta tellus. Pellentesque ligula nunc, vestibulum vel diam id, dignissim ultricies neque. Nullam laoreet dignissim dui. Praesent non eros id nisi posuere malesuada vitae quis nisl. Etiam mattis leo porta justo suscipit condimentum. Aliquam nec urna pharetra, pellentesque neque vel, aliquet libero. Phasellus hendrerit, elit ac sollicitudin venenatis, arcu metus semper urna, eu rutrum odio tellus in nisi. Aenean venenatis mauris enim. Mauris commodo nec tortor in suscipit. Proin lobortis ligula at volutpat rhoncus. Pellentesque in porta sapien. Donec semper, magna eu posuere sagittis, tellus nulla dignissim nibh, sed rutrum ante leo id neque.

Accessories

Reviews

There are no reviews yet.

Be the first to review “Fluke 721 Pressure Calibration Instruments”

Your email address will not be published. Required fields are marked *